Safer Motion Planning of Steerable Needles via a Shaft-to-Tissue Force Model

Michael Bentley, Caleb Rucker, Chakravarthy Reddy, Oren Salzman, Alan Kuntz

Research output: Contribution to journalArticlepeer-review

Abstract

Steerable needles are capable of accurately targeting difficult-to-reach clinical sites in the body. By bending around sensitive anatomical structures, steerable needles have the potential to reduce the invasiveness of many medical procedures. However, inserting these needles with curved trajectories increases the risk of tissue damage due to perpendicular forces exerted on the surrounding tissue by the needle's shaft, potentially resulting in lateral shearing through tissue. Such forces can cause significant tissue damage, negatively affecting patient outcomes. In this work, we derive a tissue and needle force model based on a Cosserat string formulation, which describes the normal forces and frictional forces along the shaft as a function of the planned needle path, friction model and parameters, and tip piercing force. We propose this new force model and associated cost function as a safer and more clinically relevant metric than those currently used in motion planning for steerable needles. We fit and validate our model through physical needle robot experiments in a gel phantom. We use this force model to define a bottleneck cost function for motion planning and evaluate it against the commonly used path-length cost function in hundreds of randomly generated three-dimensional (3D) environments. Plans generated with our force-based cost show a 62% reduction in the peak modeled tissue force with only a 0.07% increase in length on average compared to using the path-length cost in planning. Additionally, we demonstrate planning with our force-based cost function in a lung tumor biopsy scenario from a segmented computed tomography (CT) scan. By directly minimizing the modeled needle-to-tissue force, our method may reduce patient risk and improve medical outcomes from steerable needle interventions.

Original languageEnglish
Article number2350003
JournalJournal of Medical Robotics Research
Volume8
Issue number1-2
DOIs
StatePublished - 1 Jun 2023

Keywords

  • Force modeling
  • bottleneck cost function
  • continuum robots
  • motion planning
  • robotic needle steering

ASJC Scopus subject areas

  • Biomedical Engineering
  • Human-Computer Interaction
  • Computer Science Applications
  • Artificial Intelligence
  • Applied Mathematics

Fingerprint